Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 107 of 107

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
Mike Dattilio 12 months ago in UI 0 Needs review

Upgrade Steam relief to include other gas & liquid relief thrust analysis

Currently The Loads > Steam Relief > Steam Relief command enables the user to define the thrust loads at steam exit points due to a discharge through a safety relief valve. Add ability for program to analyze other gas & liquid relief val...
Mike Dattilio 9 months ago in Analysis 0 Needs review

Report Sign-Max for Support and Restraint in Results

It would be very handy for AutoPIPE to report the maximum loading for all load cases for reporting to the structural engineer or equipment manufacturers.
Sean Pellerin 6 months ago in Reporting 3 Already exists

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest over 1 year ago in AutoPIPE Pipe Stress 3 Already exists

Add Victaulic fitting

AutoPIPE can model a Victaulic fitting using a number of approach mentioned here . However this is a very difficult and demanding process. Not to mention, that in some case there are converging issues related to multiple Flexible joints on connect...
Mike Dattilio 9 months ago in Modelling 0 Future consideration

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 2 Future consideration

When exporting a model, the user should have the ability to select which nodes are exported based on the type of element it represents.

When creating stress isometric drawings, my team typically exports a .dxf file of the AutoPIPE Model. We are only concerned with nodes that represent support locations, however, there is no option to export only support nodes. Having this option a...
Guest about 3 years ago in AutoPIPE Pipe Stress 1 Future consideration

Looking for DNV-ST-F101, 2021 edition in AutoPIPE

When we will expect new DNV version in AutoPIPE
Guest about 1 year ago in Code 1 Future consideration

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio about 1 year ago in Modelling 0 Future consideration

Include UID number in "Result" mdb output.

In our work process we create PCF file using S3D. After analyzing data inside Autopipe we would like to export some of the analyzed data from Autopipe and import back to S3D. Easiest way to achieve that would be by using UID number of the analyzed...
Guest 3 months ago in Reporting 0 Needs review