All ideas

Add manufacturer library for SIF's to populate to meet B31.J as per B31.3 2020

Add manufacturer library to select for SIF's to populate to meet B31.J as per B31.3 2020
Guest about 3 years ago in Analysis 0 Needs review

Add the capability to analyse multiple piping codes in a single model (Mixed Class)

Whilst using AutoPIPE Nuclear to assess pipework to ASME III, the models included different regions of pipework that were required to be assessed to ASME III Class 1 and Class 2 respectively. As it is not possible to assess to two different piping...
Guest over 2 years ago in Analysis 4 Future consideration

Copy to clipboard button for floating load window

It would help users trying to extract maximum loads from the floating loads window if it included a copy to clipboard button which copied the loads, directions and load case to the clipboard. Currently, users have to manually type this and this ca...
Sujaan Ahamed Fareed over 1 year ago in UI 0 Needs review

User Having to Re-import .CMB File After Saving .APC File

When saving APC files, the code/non-code combinations get reset to default by AutoPIPE. User has to go though an extra step of re-importing the relevant .CMB file after saving the APC file. If there is a way to have AutoPIPE maintain the already s...
Fouad Tabbaq over 1 year ago in Reporting 1 Will not implement

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
Guest almost 4 years ago in Analysis / AutoPIPE Pipe Stress 1 Future consideration

Support Results grids local direction should be user friendly and consistent

Open the results grids, select the support tab, and locate the columns for LocalDir1 - Gap3. Quick what does this refer to: pipe local axis, support local axis? Is this direction consistent across all of the support types (see attached image of Su...
Mike Dattilio over 3 years ago in Reporting 2 Needs review

Print all Time history results in local Axis

Currently all time history results are printed in global axis. Suggest adding an option to print all Time History results (ex. Acceleration) using local pipe axis.
Mike Dattilio 3 months ago in Reporting 0 Reviewed

Include ASME B16.5 dimensions in EN1591 Flange Analysis

Currently, the EN1591 flange analysis only includes PN flange dimensions. Theoretically, you could manually input all the dimensions for an ASME flange but that would be extremely tedious to do every time. There is some ambiguity/"looseness" with ...
Sean Pellerin about 1 year ago in Analysis 2 Reviewed

Results Grids: add support Attachment ID and Directional cosign information

While the Attachment ID and Directional cosign information can be found in other results reports / dialogs, it would be very convenient to include both of these details on the results grids, support tab.
Mike Dattilio 5 months ago in UI 0 Needs review

Add features to include Type A/B fitting pressure factor for En13480 piping code

Add options into application that accommodates En13480 table A.2 specification for all fittings per En10253 requirements to define pressure factors to be applied to fittings of Type A and wall thickness requirements of fittings of Type B. Add opti...
Shrey Sharma almost 2 years ago in Analysis 1 Needs review