Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 190 of 190

Support Detail Fig # and Allowable Support Load Ratings

Ensuring support info (gaps, friction, stiffness) is correct and reviewing support results are some of the more time consuming tasks. It would be very handy to be able to set up a library of support detail figure numbers with allowable load ratings.
Sean Pellerin over 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Add climatic loads calculators according to Eurocode 1

It'l be very helpful, especialy when analyses acc. to EN 13480-3 are performed, to add to AutoPIPE calculator of wind loads acc. to EN 1991-1-4 (Eurocode 1) and calculator of snow loads acc. to EN 1991-1-3 (Eurocode 1).
Guest 11 months ago in Code 1 Needs review

Excel report manager: automatically skip missing section of selected saved report for current model

Problem: While using Excel report manager, selecting an existing save report to be applied to the current model displays the following message: "Report not compatible with the currently opened Database". This occurs because the original model use ...
Mike Dattilio 4 months ago in Reporting 0 Reviewed

Improve HIGH CONTRAST Colors

I have difficulty seeing text in AutoPIPE as it doesn't update along with high contrast in Windows.
Guest 4 months ago in UI 0 Reviewed

Add ability to analyze multiple Analysis set at the same time

Currently AutoPIPE analyzes analysis sets one at a time. Between each analysis set the application writes the results of the analysis from the cache temp folder to the model folder. Models containing multiple analysis can take an extended period o...
Mike Dattilio over 1 year ago in Analysis 0 Future consideration

Stress Isometric: populate isometric title block

Add options to export data from AutoPIPE that will to fill in attribute data for a Stress Isometric title block.
Mike Dattilio almost 3 years ago in UI 1 Needs review

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
Michael Wood about 3 years ago in UI 2 Future consideration

Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
Mike Dattilio over 1 year ago in UI 0 Needs review

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio about 3 years ago in Modelling 0 Future consideration

Consider the external pressure for ASME B31.8 / B31.4 offshore

As a subsea engineer using AutoPipe for modelling spools and jumpers, it is frustrating and misleading that AutoPipe does not account automatically for external pressure in all codes.
Guest over 1 year ago in Analysis 2 Needs review