Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 131 of 131

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest over 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Ring Tool - Ability edit or modify the settings of an existing ring

Users cannot edit or modify existing rings. This is costing significant manhours to redo Ring Placement if the user forgets something during the initial ring placement.
Sujaan Ahamed Fareed about 1 year ago in Modelling 0 Needs review

Tangent Elbows

Hi - is there a way to include consecutive elbows or bends in AutoPIPE? We have a model with back to back elbows and the model does not render the geometry well. Second, it appears that the Elbow forum is missing previous pages. Is Bentley still w...
Guest 5 months ago in Modelling 1 Already exists

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
Guest 9 months ago in UI 0 Future consideration

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest almost 2 years ago in AutoPIPE Pipe Stress 3 Already exists

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed almost 2 years ago in AutoPIPE Pipe Stress 2 Future consideration

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Ahamed Fareed almost 2 years ago in AutoPIPE Pipe Stress 0 Planned

Modal Analysis Results to include Modes Normalized

Modal Analysis Results to include Modes Normalized, the normalized result output would greatly help users locate which node points have the highest displacements where additional restraints could be needed to increase frequency at each mode results.
Guest 5 months ago in Reporting 4 Already exists

DXF & DNG export - Add extra informaiton layers

For the DXF and DGN export add new layers for Support Tag No. Anchor Tag No. Pipe Identifier Valve Tag No. Flange Tag No. etc.
Kevin Koorey 5 months ago in Reporting 0 Needs review

Update Coincident Node Check report to include Beam points

Currently, coincident node check report only returns results for pipes nodes that are within the specified tolerance distance to another pipe node point. Suggest report also include Beam points with specified tolerance distance of other Beam point...