Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

Reporting

Showing 18 of 139

Exporting .DGN of Code Stresses Color Graphics

Adding an option to export the Code Stresses Color Graphics in .DGN format? The user can utilize this feature to present the code stresses in a more visual way during the Navisworks model walk-throughs with the clients.
Fouad Tabbaq 6 days ago in Reporting 0 Needs review

Add design margins to piping loads being sent to structural

When it comes to exporting pipe support loads from AutoPIPE to STAAD, PipeLINK is an effective tool. While PipeLINK has most of the necessary functionality, there is a lack in the ability to add a Design Margin to the pipe support loads sent from ...
Guest 8 months ago in Reporting 4 Needs review

Include option to extract displacement results (at node points) in local axes

Nodal displacement results in local axes would be immensely useful. I use AutoPIPE for onshore pipelines which are not straight & reviewing the displacement locally is often needed.
Guest 9 days ago in Reporting 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
Guest 3 months ago in Reporting 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
Sean Pellerin 3 months ago in Reporting 2 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
Mike Dattilio 3 months ago in Reporting 0 Needs review

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
Gianludovico Spizuoco 9 months ago in Reporting 1 Future consideration

Modal Analysis Results to include Modes Normalized

Modal Analysis Results to include Modes Normalized, the normalized result output would greatly help users locate which node points have the highest displacements where additional restraints could be needed to increase frequency at each mode results.
Guest 6 months ago in Reporting 4 Already exists

DXF & DNG export - Add extra informaiton layers

For the DXF and DGN export add new layers for Support Tag No. Anchor Tag No. Pipe Identifier Valve Tag No. Flange Tag No. etc.
Kevin Koorey 6 months ago in Reporting 0 Needs review

Model Explorer: add the following features (ex. Tee type, Wave Type, etc..)

Please add the following features to AutoPIPE's Model Explorer: 1st approver 2nd approver Seismic code - indicate all in model to be selected Wind type - indicate all in model to be selected wave type - indicate all in model to be selected Materia...
Mike Dattilio 7 months ago in Reporting 0 Needs review