Get rid of annoying windows beep sound

This is a really annoying sound. The UI shall provide a feature to disable the annoying beep sound. The attached wiki link proposes to disable Windows Sounds, but this disables all other Windows Sounds that serve a purpose outside of Autopipe. A s...
Sujaan Ahamed Fareed over 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

User Having to Re-import .CMB File After Saving .APC File

When saving APC files, the code/non-code combinations get reset to default by AutoPIPE. User has to go though an extra step of re-importing the relevant .CMB file after saving the APC file. If there is a way to have AutoPIPE maintain the already s...
Fouad Tabbaq about 1 year ago in Reporting 1 Will not implement

PCF Import: Automatically remove flanges inserted between two Flanged Valves

When importing a PCF file with back to back valves, additional flanges are inserted between these vales as shown in attached image. PCF translator should not insert additional flanges if flanged valves are modeled back to back.
Mike Dattilio about 2 months ago in Modelling 0 Future consideration

We would like the ability to compare two AutoPIPE models against each other for the purpose to locating changes as new models are created.

Our current work process is to receive PCF's from the 3D design model, translate, analysis and suggest changes if needed to the design team, then repeat as the 3D model changes. Currently the only way to see design changes is to visually search th...
Guest about 2 months ago in AutoPIPE Pipe Stress 0 Needs review

Allow small letters in point names to increase node limit to 40000

If increasing the length of point names to 5 or six letters is too hard, I suggest allowing the use of small letters aa to zz. This will increase the number of segments and number of nodes by 4 times to about 2800 segments and 40,000 nodes.
Karim Rinawi about 2 months ago in Analysis 0 Future consideration

Request for API Support to Capture Model Snapshots in AutoPIPE

Can AutoPIPE provide a programmatic interface (via Python, VBA, or any other API) to automatically capture graphical snapshots or view-specific images from the model environment? This would greatly enhance reporting and documentation workflows, es...
Saladi Venkata Srirama Chandra Murthy 7 months ago in AutoPIPE Pipe Stress 0 Reviewed

Piping comparison feature

When systems are revised it would be useful if a user could import new files from designers and see them directly on top of existing systems. This would allow a user to be able to visually see and measure changes. Updated files can be imported but...
Guest 7 months ago in Modelling 1 Needs review

Add ASCE-7-22

For wind loading ASCE-7-22 needs to be added in selection list. This is the latest standard and client design basis is demanding to use latest standard.
Guest about 2 months ago in Analysis 0 Planned

Separate the Support Forces Global Direction column by x, y, and z

About the support forces of the Excel Report of the report manager The Global_Direction outputs the same column, but users need to separate them by X, Y, Z. Please develop the AutoPIPE to separate the column by x, y, and z?
Yasushi Nagao 4 months ago in Reporting 1 Future consideration

Add manufacturer library for SIF's to populate to meet B31.J as per B31.3 2020

Add manufacturer library to select for SIF's to populate to meet B31.J as per B31.3 2020
Guest over 2 years ago in Analysis 0 Needs review