Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 3

Release limitation of PIPE ID character length

Users of a company in Japan name PIPE ID under specific rule in P&ID and 3D-CAD while AutoPIPE has a limitation for PIPE ID's character length as 8 words. So they convert the PIPE ID for AutoPIPE limitation, but there is a possibility that it ...
Yasushi Nagao over 2 years ago in AutoPIPE Pipe Stress 2 Will not implement

Why there is no option what components to show after clicking the show component dialog box

Hello,When you work with a model that consiously you hide different kind of components in it, and then you want to show only one kind of hidden components for example the guide supports, it turns out that such a function does not exist in Autopipe...
Wojciech Augustyn over 1 year ago in AutoPIPE Pipe Stress 1 Will not implement

Option to un-check B31J

There should be option to un-check B31J even if we use Ed.2020. This will help during anlaysis which comprises of both ASME Sec-1 & B31.1 pipes. Hence there should be an option to uncheck if not required. By default it should be “ticked” but i...
Guest almost 2 years ago in AutoPIPE Pipe Stress 1 Will not implement