Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains at 375F, but proposed piping heats from 70-375F. Case 2: Header and proposed piping are shut down to 70F. Header goes from 375F to 70F, proposed piping goes from 375F to 70F.


Mike Dattilio: Unfortunately, as of Aug 2024, AutoPIPE only has one ambient temperature setting. However, this is a good idea, and I can see the value of it.