A need to track displacements of reference points?

how to track displacements of reference points? I understand that reference points are only used to track forces and moments but i want to see separately the displacement results of these reference points instead of manually searching node by node...
Guest 4 months ago in Analysis 1 Needs review

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest over 1 year ago in AutoPIPE Pipe Stress 3 Already exists

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
Mike Dattilio over 1 year ago in UI 0 Needs review

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 2 Future consideration

Add capability to model 2 springs in series

Spring hanger arrangement, see attachment.
Mike Dattilio 12 months ago in Modelling 0 Needs review

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 0 Planned

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest about 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Extract system Response Spectra at decoupled connection points

The capability of producing FRS at some points is sometimes needed to analyze small bore branches. Generally, the small bore branches could be decoupled from the headers for seismic analysis, but these lines shall be evaluated separately using the...
Guest 4 months ago in AutoPIPE Pipe Stress 3 Future consideration

Color plot: Connected Segments

Provide a color map based on the Connected Segments (Select > Segments > Connected Segments). For each disconnected group have a unique color assigned.
Mike Dattilio about 1 year ago in Modelling 0 Needs review

Upgrade Steam relief to include other gas & liquid relief thrust analysis

Currently The Loads > Steam Relief > Steam Relief command enables the user to define the thrust loads at steam exit points due to a discharge through a safety relief valve. Add ability for program to analyze other gas & liquid relief val...
Mike Dattilio about 1 year ago in Analysis 0 Needs review