ADD A NEW IDEA

FILTER BY CATEGORY

All ideas

Showing 22 of 22

Release limitation of PIPE ID character length

Users of a company in Japan name PIPE ID under specific rule in P&ID and 3D-CAD while AutoPIPE has a limitation for PIPE ID's character length as 8 words. So they convert the PIPE ID for AutoPIPE limitation, but there is a possibility that it ...
Guest 5 months ago in Modeling 0

100-40-40 spatial combination option

In Response Spectra Analysis, the spatial combination is always SRSS. The NRG 1.92 rev. 2 accepts as an alternative the use of the 100-40-40 method, as proposed by Newmark, to spatially combine the components. An option to select between SRSS or 1...
Edgar Flores 26 days ago in Analysis 0

When exporting a model, the user should have the ability to select which nodes are exported based on the type of element it represents.

When creating stress isometric drawings, my team typically exports a .dxf file of the AutoPIPE Model. We are only concerned with nodes that represent support locations, however, there is no option to export only support nodes. Having this option a...
Guest 11 months ago in  1

Add line number attribute to drawing table ISO stress

No description provided
Guest 3 months ago in Reporting 0

Flange analysis EN 1591-1

Include EN1591-1 calculations methodology for flanges / flange leakageLook through EN 13445-3 Annex G - Alternative design rules for flanges and gasketed flange connections
Guest 9 months ago in  1 Planned

Include B31.1 2020 option

No description provided
Guest 10 months ago in Code 1 Planned

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest 9 months ago in Modeling 0 Planned

Combination Reorganization

In the screenshot in the attached link, for example, i would like to move the highlighted combinations between LC130 and LC131. Does this make sense? As far as I know, the only way to do this is to duplicate LC131 to LC148 and then delete them. Li...
Guest 11 months ago in  1

Add color-coded presentation of P&ID line numbers assigned to AutoPIPE model segments

This kind of presentation allows for model data analysis in order to see pipes according to their P&ID line numbers. It is VERY needed as allows to verify which segments represent which lines. Also may by used to represent equipment, equipment...
Guest 10 months ago in  0

Always enable "Use weight factor for bolt/nut weight" when importing a flange

When importing a PCF file please allow for the option to enabler "Use weight factor for bolt/nut weight" for flanges
Guest 4 months ago in Analysis 0