Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio about 1 year ago in Modelling 0 Future consideration

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest almost 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

display miter bends

When a bend is a miter display with the number of cuts or at least just one cut so they do not look like formed bends.
Kevin Koorey 11 months ago in Modelling 0 Needs review

Second UI Window for docking dialogs, tools and grids

Autopipe has multiple windows, tools, floating windows, grids and other UI Elements. For users that use multiple monitors, The above UI Elements often move around, and re orient themselves. By providing the user with a second UI Application Window...
Sujaan Ahamed Fareed about 1 year ago in AutoPIPE Pipe Stress / UI 1 Future consideration

Include UID number in "Result" mdb output.

In our work process we create PCF file using S3D. After analyzing data inside Autopipe we would like to export some of the analyzed data from Autopipe and import back to S3D. Easiest way to achieve that would be by using UID number of the analyzed...
Guest 4 months ago in Reporting 0 Needs review

Fix the Load Sequencing for Snow Load

The help file states the following for snow load analysis: Limitation Currently, AutoPIPE only considers snow loading as linear analysis. Load sequencing does not apply to snow loads and such results should not be considered. For analysis sets tha...
Sean Pellerin 8 months ago in Analysis 0 Needs review

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
Michael Wood over 1 year ago in AutoPIPE Pipe Stress 1 Future consideration

Add label box for flexible joints

It would be helpful if flexible joints could have a label or tag added. This would be similar to how many components in AutoPIPE have the ability to label components, such as supports and anchors.
Michael Cummings about 1 year ago in UI 1 Future consideration

A single Autopipe file

Similar to APC files, it would be much more convenient if Autopipe packaged all essential sub files during an analysis project and created a single file by default. It would ensure that the user does not make a mistake and stores the wrong files. ...
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 5 Already exists

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest 8 months ago in Reporting 1 Future consideration