Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 141 of 141

Consider the external pressure for ASME B31.8 / B31.4 offshore

As a subsea engineer using AutoPipe for modelling spools and jumpers, it is frustrating and misleading that AutoPipe does not account automatically for external pressure in all codes.
Guest 6 months ago in Analysis 2 Needs review

Flexible Joint Step Function Stiffness

Looking for an update to flex coupling input box to better model flexible coupling behavior. Flexible joint additional inputs (see attached) 1) Max angle of deflection for flex joint 2) Two stiffness inputs for bending stiffness. Stiffness changes...
Guest over 1 year ago in Modelling 0 Future consideration

Apply wind Shape factor to pipe properties instead of everything as it varies due to geometry in AS1170.2

You currently only have 1 place to input the Wind shape factor and this is applied to all pipes but the value is different for each diameter in Accordance with AS1170.2. This value could be input in the pipe properties for individual pipe sizes, t...
Paul Nielsen about 1 month ago in Analysis 0 Needs review

Wind Load calculator for AS1170.2 for Australia

This would save time with setting up wind loads, anyone designing in australia would benefit. Competitors software already has this
Paul Nielsen about 1 month ago in Code 0 Needs review

ADD DVS (DVS 2210/DVS 2205) code

The DVS code is a technical code which includes fundamentals for the design, calculation, prefabrication and assembly of industrial piping made of thermoplastics and laid above ground. More clients are requesting for this code and would be a great...
Guest about 1 month ago in AutoPIPE Pipe Stress 0 Needs review

Add option in pipe support data "Support", column for "Rigid for Hydrotest"

Pls add option in the pipe support "Support" data, column to allow users option to check mark pipe support node points where spring rate/stiffness are provided. (Note: for spring types, default will have the check-mark activated). For example, usi...
Guest about 1 month ago in Analysis 0 Needs review

Add API 661 allowables to rotating equipment

Provide user ability to insert cooler nozzle allowables per API 661. This would help with cooler orientation and no longer require user to look up allowable values each time. Provide a multiplier allowable (i.e. 2x 3x API limits)
Guest about 1 year ago in Analysis 0 Future consideration

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
Guest almost 2 years ago in Analysis / AutoPIPE Pipe Stress 0 Future consideration

Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
Mike Dattilio 5 months ago in UI 0 Needs review

Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains ...
Guest 5 months ago in Analysis 0 Needs review