Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 119 of 120

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
Guest 6 months ago in Analysis 0 Future consideration

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
Gianludovico Spizuoco 6 months ago in Reporting 1 Future consideration

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
Guest 7 months ago in UI 0 Future consideration

User .DFL file as seed file for project specification

AutoPIPE currently provides a default setting file that can be used to control how a new model is created. We want to expand this to include most options, settings and material information, make it shareable and use it as a seed file. Would this b...
Phil Senior 11 months ago in Modelling 0 Planned

Add Cut-shorts to View Settings/Scale Factors

Users cannot change the size of cut-short symbol. The cut-short symbol is drawn proportional to the pipe OD while in single line mode. It sometimes looks too big or too small.
Guest 11 months ago in UI 0 Needs review

Report Sign-Max for Support and Restraint in Results

It would be very handy for AutoPIPE to report the maximum loading for all load cases for reporting to the structural engineer or equipment manufacturers.
Sean Pellerin 11 months ago in Reporting 3 Already exists

Fix the Load Sequencing for Snow Load

The help file states the following for snow load analysis: Limitation Currently, AutoPIPE only considers snow loading as linear analysis. Load sequencing does not apply to snow loads and such results should not be considered. For analysis sets tha...
Sean Pellerin about 1 year ago in Analysis 0 Needs review

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest about 1 year ago in Reporting 1 Future consideration

Model new piping geometry based on newly established local coordinate system instead of Global coordinate system

Use Case: If The entire model is using plant coordinates thus causing the entire system to be off AutoPIPE's global axis. Then, if the user needs to add new piping geometry it is very difficult to model in AutoPIPE using global coordinates. Users ...
Mike Dattilio about 1 year ago in Modelling 0 Needs review

Add China Electric Power industry standard DL/T 5366

At present, the pipeline stress calculation specification is selected as the American standard, whether it is considered to refer to the Chinese standard DL/T 5366-2014. If there is no reference to this standard, then please ask whether this stand...
Mike Dattilio about 1 year ago in Code 0 Needs review