Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 153

Provide button to run analysis when it detects outdated results

Currently, AutoPIPE warns the user when it detects outdated results when the user tries to open the Results Grid. Instead of just warning the user, and deleting the outdated results, why doesn't AutoPIPE just rerun the analysis, or at least provid...
Sujaan Ahamed Fareed 7 months ago in UI 0 Planned

Ring Tool - Ability to modify angles in the Ring Tool dialog

When a user defines custom projections in the Ring Tool dialog, and then realizes they need to add an additional angle, it is not possible. The current method requires the user to clear out the custom angles defined and reenter the custom defined ...
Sujaan Ahamed Fareed over 1 year ago in Modelling 0 Needs review

Toggle Between v12 Result Grid and v24 Result Grid

The v12 Result grid was a much simpler, leaner, and straightforward method to data processing for the excel oriented layout it had. With the v24 Result grid, we CANNOT select any of the columns independently as previously on v12. This completely r...
Guest 8 months ago in UI 5 Will not implement

Adding a calculation module acc. to EN 13445 in AutoPIPE Nozzle/Vessel

When analyzing nozzle loads acc. to EN 13445 designed vessels.
Guest almost 2 years ago in AutoPIPE Pipe Stress 1 Planned

Reference Loads - Results Database

Currently, AutoPIPE does not have the option to export reference loads to a .mdb file. I want to be able to easily compare the Reference Loads to their allowable. This is most handy when you have radial nozzles. Please include the allowable loads ...
Sean Pellerin over 2 years ago in AutoPIPE Pipe Stress 1 Future consideration

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
Michael Wood over 2 years ago in AutoPIPE Pipe Stress 2 Future consideration

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
Mike Dattilio almost 2 years ago in UI 0 Needs review

支架选择中增加固定支架选项

管系应力分析计算时,经常需要设置固定支架,该支架承受垂直、水平、径向三个方向(即轴系中 xyz三向)的 力,且此处三向位移均约束 0。现有支架选项只能通过滑动支架+限位支架组合实现该功能。但是计算结果输出到路草支吊架软件时,会自动视别 为两个支架。 When calculating the stress analysis of the piping system, it is often necessary to set a fixed bracket, which bears the f...
Guest 4 months ago in AutoPIPE Pipe Stress 1 Needs review

When exporting a model, the user should have the ability to select which nodes are exported based on the type of element it represents.

When creating stress isometric drawings, my team typically exports a .dxf file of the AutoPIPE Model. We are only concerned with nodes that represent support locations, however, there is no option to export only support nodes. Having this option a...
Guest about 4 years ago in AutoPIPE Pipe Stress 1 Future consideration

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio about 2 years ago in Modelling 0 Future consideration