Hydrotest Pressure Extension

Users can decide whether pressure extension should be considered in static analysis sets, but this is not an option for hydrotest cases. The user is required to consider it with no option to unselect "Pressure Extension" in the "Analysis Sets" int...
Guest 10 months ago in Analysis 2 Future consideration

Defining Concentrated force to the local axis of element

The inability to specify the concentrated force for the local element in Autopipe leads to numerous challenges when defining the slug force on a pipeline that is misaligned with the axis. In contrast to CAESAR, Autopipe lacks the capability to rot...
Guest 10 months ago in Analysis 0 Planned

Include UID number in "Result" mdb output.

In our work process we create PCF file using S3D. After analyzing data inside Autopipe we would like to export some of the analyzed data from Autopipe and import back to S3D. Easiest way to achieve that would be by using UID number of the analyzed...
Guest 11 months ago in Reporting 0 Needs review

Flexible elements displacement results in element local axes

having flexible elements displacements results reported in local element axes, provides a better way to quantify relative end displacements and avoids doing global to local axes transformation out of the software. Amount of end and intermediate di...
Guest about 1 year ago in AutoPIPE Pipe Stress 1 Already exists

"Selection types different" - Develop a permanent solution for this error

https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/18879/selection-types-different-message-occurs-when-copy-pasting-to-autopipe Develop a permanent solution for this bug since 2015. Copy and pasting rows fro...
Sujaan Ahamed Fareed about 1 year ago in Modelling 0 Needs review

Output file should describe number of Warning/Error conditions encountered

Analysis quality will improve if AutoPIPE Output Report (SQO) describes the number of Warning/Error conditions encountered together with a recommendation to view .CHK, .DCHK, .ANL and any other Warning/Error files present. The lack of a recommenda...
Guest over 1 year ago in Analysis 0 Needs review

Write as many Error messages as possible to *.ANL file

Currently Error messages appear on screen while interactively using AutoPIPE. If doing Batch processing Error messages never appear! If an Error message can be displayed on the screen it can also be written to the *.ANL file. Error conditions that...
Guest over 1 year ago in Reporting 0 Planned

Increase the number of SAM / Support Groups

AS of AutoPIPE 23.00.00.230, the maximum number of unique response spectrums that can be analyzed is 200 [(S1..S10)x 20 support groups per SAM case]. Suggest to Increase the number of SAM and/or Support Groups in order to allow 200+ unique respons...
Mike Dattilio over 1 year ago in Analysis 0 Needs review

Create and Save selection set of node points and beam points

As of July 2023, after making a selection set (highlighted red) it may become unselected when choosing the next command or another location that is not apart of the selection set. The user may need to perform another command / modification to a pr...
Mike Dattilio over 1 year ago in Modelling 1 Needs review

Support Results grids local direction should be user friendly and consistent

Open the results grids, select the support tab, and locate the columns for LocalDir1 - Gap3. Quick what does this refer to: pipe local axis, support local axis? Is this direction consistent across all of the support types (see attached image of Su...