Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 111 of 111

Add label box for flexible joints

It would be helpful if flexible joints could have a label or tag added. This would be similar to how many components in AutoPIPE have the ability to label components, such as supports and anchors.
Michael Cummings about 1 year ago in UI 1 Future consideration

Include UID number in "Result" mdb output.

In our work process we create PCF file using S3D. After analyzing data inside Autopipe we would like to export some of the analyzed data from Autopipe and import back to S3D. Easiest way to achieve that would be by using UID number of the analyzed...
Guest 4 months ago in Reporting 0 Needs review

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest 9 months ago in Reporting 1 Future consideration

Allow user to set the 6 color stress plot ranges as needed

While looking at the Color Stress plot there is a Key in the top left corner with 6 colors and corresponding ranges. These ranges are hard coded into the program. Give the user the options to set these 6 ranges as needed.
Mike Dattilio about 1 year ago in UI 2 Future consideration

Model new piping geometry based on newly established local coordinate system instead of Global coordinate system

Use Case: If The entire model is using plant coordinates thus causing the entire system to be off AutoPIPE's global axis. Then, if the user needs to add new piping geometry it is very difficult to model in AutoPIPE using global coordinates. Users ...
Mike Dattilio 9 months ago in Modelling 0 Needs review

Apply joint efficiency factor to ASME B31.1 Expansion allowable

As an example, ASME B31.1 (2020) - section "102.3.2 Limits for Sustained Stresses and Displacement Stress Ranges" - para (b) Displacement Stresses provides the equation 1A for calculation of allowable stress range. Review the definition of Sc and ...
Mike Dattilio about 1 year ago in Analysis 2 Future consideration

Bolt Pre Tension

Possibility to declare bolt pre tension (eg, 40% or 50% of bolt SMYS) has to be provided in the Flange check.
Guest almost 2 years ago in AutoPIPE Pipe Stress 0 Needs review

Add China Electric Power industry standard DL/T 5366

At present, the pipeline stress calculation specification is selected as the American standard, whether it is considered to refer to the Chinese standard DL/T 5366-2014. If there is no reference to this standard, then please ask whether this stand...
Mike Dattilio 10 months ago in Code 0 Needs review

Copy & pasting pipe components with existing soil Id's are not updated with new Soil Id names

Open PipeSoil.apc Notice the Soil id currently in the model. Select all of the model. Paste to any location after pasting, notice the number of Soil Id's has doubled. Recommend when coping / pasting pipe node points with existing Soil Id's that th...
Mike Dattilio 10 months ago in Modelling 0 Needs review

Looking for an update to Import/Export the file from UG-Nx to Autopipe or Vice versa. Currently there is no common format's available which will support both the softwares.

Looking for an update to Import/Export the file from Auto-Pipe to UG-Nx or Vice versa. Currently there is no common format's available which will support both the software's.
Guest 11 months ago in AutoPIPE Pipe Stress 4 Needs review