Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
Gianludovico Spizuoco about 2 months ago in Reporting 1 Future consideration

Add a toggle button in segments grid to apply a transparency visual plot

Working with existing or future segments in large systems, it would be great to have a option to change their segments plot (like adding transparency). Something similar to older software like Triflex (see attached image).
Guest 3 months ago in UI 2 Future consideration

Develop an Python API plug-in for importing, building, and editing models using data from 3D CAD packages

Develop an API that allows writing Python scripts to post process Autopipe results data for automated reporting etc. Also, allow plug-in for building and editing models using data from 3D CAD packages. (1018304)
Mike Dattilio 11 months ago in UI 5 Planned

Update Materials List & Temp Range to reflect that of the code (B31.3)- Specifically N08811

If the material is listed in the code (B31.3) shouldn't it be in list of materials in the software and also have the same temperature range
Guest 4 months ago in Code 3 Future consideration

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
Guest about 1 year ago in Analysis / AutoPIPE Pipe Stress 0 Future consideration

Generate Floor Response Spectra (FRS) at certain locations

The capability of producing FRS at some points is sometimes needed to analyze small bore branches. Generally, the small bore branches could be decoupled from the headers for seismic analysis, but these lines shall be evaluated separately using the...
Guest about 1 month ago in AutoPIPE Pipe Stress 1 Needs review

Non-nuclear Fatigue Analysis

I am planning to include non-nuclear fatigue in a future release. We already support ASME III NB method for nuclear and want to provide a general approach to be used with other design codes. I am looking for interest in the idea and any suggestion...
Phil Senior 8 months ago in Analysis 2 Future consideration

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
Guest 2 months ago in UI 0 Planned

ASME Flange Summary to show both Operating and Seating in separate columns

Currently the results summary will show the worst case for the flange. ASME B16.5 flanges combined with spiral wound gaskets will commonly fail the seating condition check with the ASME division 1 checks. This can be ignored provided the operating...
Guest about 1 month ago in Reporting 0 Future consideration

Get rid of annoying windows beep sound

This is a really annoying sound. The UI shall provide a feature to disable the annoying beep sound. The attached wiki link proposes to disable Windows Sounds, but this disables all other Windows Sounds that serve a purpose outside of Autopipe. A s...
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 0 Future consideration