Add Node Annotations to stress isometric

AutoPIPE's Node Annotations (Insert > Node Annotations) are not able to be printed on a Stress Isometric. Using the "save isometric drawning" prompt, we have the option to isert annotations (but it's not a good way to do it), and it's not relat...
Guest almost 2 years ago in Modelling 0 Needs review

Adding a calculation module acc. to EN 13445 in AutoPIPE Nozzle/Vessel

When analyzing nozzle loads acc. to EN 13445 designed vessels.
Guest about 2 years ago in AutoPIPE Pipe Stress 1 Planned

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
Mike Dattilio about 2 years ago in UI 0 Needs review

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio about 2 years ago in Modelling 0 Future consideration

Add features to include Type A/B fitting pressure factor for En13480 piping code

Add options into application that accommodates En13480 table A.2 specification for all fittings per En10253 requirements to define pressure factors to be applied to fittings of Type A and wall thickness requirements of fittings of Type B. Add opti...
Shrey Sharma 4 months ago in Analysis 0 Needs review

Limit License selection to what is available to the account

On the configuration dialog, the user is given the option to select a number of different editions of AutoPIPE: Standard, Advanced, Nuclear. Suggest to grey out options that are not available to the account. Example: Account only has AutoPIPE Stan...
Mike Dattilio 7 months ago in UI 0 Needs review

Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
Mike Dattilio 10 months ago in UI 0 Needs review

Consider the external pressure for ASME B31.8 / B31.4 offshore

As a subsea engineer using AutoPipe for modelling spools and jumpers, it is frustrating and misleading that AutoPipe does not account automatically for external pressure in all codes.
Guest 11 months ago in Analysis 2 Needs review

Update Materials List & Temp Range to reflect that of the code (B31.3)- Specifically N08811

If the material is listed in the code (B31.3) shouldn't it be in list of materials in the software and also have the same temperature range
Guest over 1 year ago in Code 4 Future consideration

Ring Tool - Ability to modify angles in the Ring Tool dialog

When a user defines custom projections in the Ring Tool dialog, and then realizes they need to add an additional angle, it is not possible. The current method requires the user to clear out the custom angles defined and reenter the custom defined ...
Sujaan Ahamed Fareed over 1 year ago in Modelling 0 Needs review