Add option in pipe support data "Support", column for "Rigid for Hydrotest"

Pls add option in the pipe support "Support" data, column to allow users option to check mark pipe support node points where spring rate/stiffness are provided. (Note: for spring types, default will have the check-mark activated). For example, usi...
Guest 24 days ago in Analysis 0 Needs review

Add the capability to analyse multiple piping codes in a single model

Whilst using AutoPIPE Nuclear to assess pipework to ASME III, the models included different regions of pipework that were required to be assessed to ASME III Class 1 and Class 2 respectively. As it is not possible to assess to two different piping...
Guest 5 months ago in Analysis 4 Future consideration

Add manufacturer library for SIF's to populate to meet B31.J as per B31.3 2020

Add manufacturer library to select for SIF's to populate to meet B31.J as per B31.3 2020
Guest about 1 year ago in Analysis 0 Needs review

Consider the external pressure for ASME B31.8 / B31.4 offshore

As a subsea engineer using AutoPipe for modelling spools and jumpers, it is frustrating and misleading that AutoPipe does not account automatically for external pressure in all codes.
Guest 5 months ago in Analysis 2 Needs review

Flexible Joint Step Function Stiffness

Looking for an update to flex coupling input box to better model flexible coupling behavior. Flexible joint additional inputs (see attached) 1) Max angle of deflection for flex joint 2) Two stiffness inputs for bending stiffness. Stiffness changes...
Guest over 1 year ago in Modelling 0 Future consideration

Add colour mapped view according Line Number assigned to segments

In the project assessment phase it is necessary to compare if the model is in accordance with P&ID schematics. Presentation with colors assigned to Line Numbers would be VERY helpful in this task.
Maciej Rydlewicz about 1 month ago in Modelling 1 Already exists

Add a button in Help>Online Resources that links to the most recent release

Have a newcomer or an old timer try to navigate all the difference paths available to try to find where to download the most recent release. How long does it take? Too long. Add a button in Help>Online Resources that links to the most recent re...
Guest about 1 month ago in UI 0 Needs review

Add Node/Support point text leader lines

When using AutoPIPE or relating an output report to a model, users need to be able to clearly read the indicated text on screen / screen shot added into an report. This is not easy in congested areas with how AutoPIPE currently displays informatio...
Mike Dattilio 4 months ago in UI 0 Needs review

Add API 661 allowables to rotating equipment

Provide user ability to insert cooler nozzle allowables per API 661. This would help with cooler orientation and no longer require user to look up allowable values each time. Provide a multiplier allowable (i.e. 2x 3x API limits)
Guest about 1 year ago in Analysis 0 Future consideration

Add option to connect disconnected segments after PCF or other import

Very often we are tasked of cleaning an imported PCF or other imports. We notice quite a few disconnected segments as evident with anchors at the middle of runs. Very often the PCF import tolerance does not work, and many disconnections are import...
Karim Rinawi about 1 month ago in  0 Needs review