Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

FILTER BY CATEGORY

Analysis

Showing 12 of 47

Increase maximum number of static earthquake load cases.

When using nonlinear analysis earthquake loads cannot be scaled. If additional analysis sets are required with different earthquake accelerations for design purposes, it is severely limiting to have only 30 E cases. There are 100 analysis sets, it...
Michael Wood 25 days ago in Analysis 0

Please delete it.

No description provided
Guest 12 days ago in Analysis 0

Add feature to easily check displacements at either end of an expansion joint or flexible connection for comparison with manufacturers allowables

No description provided
Guest 6 months ago in Analysis 1 Planned

Bolt Pre Tension

Possibility to declare bolt pre tension (eg, 40% or 50% of bolt SMYS) has to be provided in the Flange check.
Guest 9 months ago in Analysis 0

ASME NM.2 Analysis

ASME released a new FRP standard for pipe stress analysis in 2019. This would be very beneficial for FRP analysis compared to ASME B31.3.
Sean Pellerin 3 months ago in Analysis 0

Always enable "Use weight factor for bolt/nut weight" when importing a flange

When importing a PCF file please allow for the option to enabler "Use weight factor for bolt/nut weight" for flanges
Guest over 1 year ago in Analysis 0

Use AutoPIPE valve weights when importing PCF files

When importing files (such as PCF's) please provide the option to use AutoPIPE valve weights rather than using the weights from the original design tool that created the PCF file. Essentially having the option to automatically enable the "valve wr...
Guest over 1 year ago in Analysis 0

Option to un-check B31J

There should be option to un-check B31J even if we use Ed.2020. This will help during anlaysis which comprises of both ASME Sec-1 & B31.1 pipes. Hence there should be an option to uncheck if not required. By default it should be “ticked” but i...
Guest 9 months ago in Analysis 1 Will not implement

Allow gap supports with response spectra analysis

Response spectrum analysis is a static equivalent linear analysis to a dynamic earthquake event. AutoPIPE allows the use of V-Stops with gaps for static analysis. The condition of the gap closure and subsequent support loading is determined by eva...
Guest 10 months ago in Analysis 0 Planned

Allow stresses from soils to be combined with other pipe stress loads in user defined combinations

Currently ring bending stresses in pipes from soil loads cannot be exported within a separate user-defined load combination (like gravity / thermal / poisson loads etc.) but has to be exported as part of a very specific pre-determined code combina...
Guest 10 months ago in Analysis 0