Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 129 of 129

Option to calculate transportational vibrations during shipment of the pipes

Currently, there is no option to analyze transportational vibrations on a pipe line when it is being shipping to a different location, specially for skid mounted piping. This allows users to identify shipping supports which can be removed after th...
Guest 5 days ago in Analysis 0 Needs review

PCF import: Provide better material mapping, e.g. use PIPING-SPEC

This is related to the limitation on the PCF Attribut Mapping tab. If we had the ability to map the PIPING-SPEC to a material then this issue would have been very easy to resolve.
Karim Rinawi 6 days ago in AutoPIPE Pipe Stress 0 Needs review

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
Guest about 1 month ago in AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
Guest about 1 month ago in Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
Guest about 1 month ago in Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
Sean Pellerin about 1 month ago in Reporting 2 Needs review

Add ASME B31.9 Code

Pls add ASME B31.9 Code.
Guest about 1 month ago in Code 0 Future consideration

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
Mike Dattilio about 2 months ago in Reporting 0 Needs review

Provide button to run analysis when it detects outdated results

Currently, AutoPIPE warns the user when it detects outdated results when the user tries to open the Results Grid. Instead of just warning the user, and deleting the outdated results, why doesn't AutoPIPE just rerun the analysis, or at least provid...
Sujaan Ahamed Fareed about 2 months ago in UI 0 Planned

Import multiple load cases from pcf files

We are trying to reduce the steps required to edit piping in initial design. We have multiple transients that all have to be accounted for. In order to hold a consistent model, we are trying to make any and all changes in SolidWorks and import int...
Guest about 2 months ago in UI 6 Planned