ADD A NEW IDEA

All ideas

Showing 129 of 129

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest over 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
Guest 9 months ago in UI 0 Future consideration

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest almost 2 years ago in AutoPIPE Pipe Stress 3 Already exists

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed almost 2 years ago in AutoPIPE Pipe Stress 2 Future consideration

Modal Analysis Results to include Modes Normalized

Modal Analysis Results to include Modes Normalized, the normalized result output would greatly help users locate which node points have the highest displacements where additional restraints could be needed to increase frequency at each mode results.
Guest 5 months ago in Reporting 4 Already exists

DXF & DNG export - Add extra informaiton layers

For the DXF and DGN export add new layers for Support Tag No. Anchor Tag No. Pipe Identifier Valve Tag No. Flange Tag No. etc.
Kevin Koorey 5 months ago in Reporting 0 Needs review

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Ahamed Fareed almost 2 years ago in AutoPIPE Pipe Stress 0 Planned

Update Coincident Node Check report to include Beam points

Currently, coincident node check report only returns results for pipes nodes that are within the specified tolerance distance to another pipe node point. Suggest report also include Beam points with specified tolerance distance of other Beam point...
Mike Dattilio 5 months ago in Modelling 0 Needs review

Add capability to model 2 springs in series

Spring hanger arrangement, see attachment.
Mike Dattilio about 1 year ago in Modelling 0 Needs review

Model Explorer: add the following features (ex. Tee type, Wave Type, etc..)

Please add the following features to AutoPIPE's Model Explorer: 1st approver 2nd approver Seismic code - indicate all in model to be selected Wind type - indicate all in model to be selected wave type - indicate all in model to be selected Materia...