Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 53

Add a toggle button in segments grid to apply a transparency visual plot

Working with existing or future segments in large systems, it would be great to have a option to change their segments plot (like adding transparency). Something similar to older software like Triflex (see attached image).
Guest 10 months ago in UI 2 Future consideration

Update Materials List & Temp Range to reflect that of the code (B31.3)- Specifically N08811

If the material is listed in the code (B31.3) shouldn't it be in list of materials in the software and also have the same temperature range
Guest 11 months ago in Code 4 Future consideration

Add API 661 allowables to rotating equipment

Provide user ability to insert cooler nozzle allowables per API 661. This would help with cooler orientation and no longer require user to look up allowable values each time. Provide a multiplier allowable (i.e. 2x 3x API limits)
Guest about 1 year ago in Analysis 0 Future consideration

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest over 1 year ago in Reporting 1 Future consideration

Add Victaulic fitting

AutoPIPE can model a Victaulic fitting using a number of approach mentioned here . However this is a very difficult and demanding process. Not to mention, that in some case there are converging issues related to multiple Flexible joints on connect...
Mike Dattilio over 1 year ago in Modelling 2 Future consideration

Model Square pipe / ducting

Add the ability to model square piping / ducting
Mike Dattilio over 1 year ago in Modelling 1 Future consideration

Add label box for flexible joints

It would be helpful if flexible joints could have a label or tag added. This would be similar to how many components in AutoPIPE have the ability to label components, such as supports and anchors.
Michael Cummings over 1 year ago in UI 1 Future consideration

Flexible Joint Step Function Stiffness

Looking for an update to flex coupling input box to better model flexible coupling behavior. Flexible joint additional inputs (see attached) 1) Max angle of deflection for flex joint 2) Two stiffness inputs for bending stiffness. Stiffness changes...
Guest over 1 year ago in Modelling 0 Future consideration

Allow user to set the 6 color stress plot ranges as needed

While looking at the Color Stress plot there is a Key in the top left corner with 6 colors and corresponding ranges. These ranges are hard coded into the program. Give the user the options to set these 6 ranges as needed.
Mike Dattilio over 1 year ago in UI 2 Future consideration

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio over 1 year ago in Modelling 0 Future consideration