AutoPIPE Pipe Stress

Showing 151 of 154

Add a button that resets the Input Grids or Results grids to visible location on screen

When using AutoPIPE on laptop connected to a docking station or additional monitors, then removed to just using a laptop screen may cause the input / results grids to not be shown in the visible area. The grids are hidden out of screen view. Recom...
Mike Dattilio almost 2 years ago in UI 0 Needs review

PCF import: Provide better material mapping, e.g. use PIPING-SPEC

This is related to the limitation on the PCF Attribut Mapping tab. If we had the ability to map the PIPING-SPEC to a material then this issue would have been very easy to resolve.
Karim Rinawi 5 months ago in AutoPIPE Pipe Stress 0 Needs review

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest almost 4 years ago in AutoPIPE Pipe Stress 0 Future consideration

Looking for an update to Import/Export the file from UG-Nx to Autopipe or Vice versa. Currently there is no common format's available which will support both the softwares.

Looking for an update to Import/Export the file from Auto-Pipe to UG-Nx or Vice versa. Currently there is no common format's available which will support both the software's.
Guest over 1 year ago in AutoPIPE Pipe Stress 5 Needs review

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest about 2 years ago in AutoPIPE Pipe Stress 3 Already exists

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed about 2 years ago in AutoPIPE Pipe Stress 2 Future consideration

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Ahamed Fareed about 2 years ago in AutoPIPE Pipe Stress 0 Planned

Ring Tool - Ability edit or modify the settings of an existing ring

Users cannot edit or modify existing rings. This is costing significant manhours to redo Ring Placement if the user forgets something during the initial ring placement.
Sujaan Ahamed Fareed over 1 year ago in Modelling 0 Needs review

Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
Guest 6 months ago in AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
Guest 6 months ago in Reporting 0 Needs review