Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 119

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
Guest 7 months ago in UI 0 Future consideration

When exporting a model, the user should have the ability to select which nodes are exported based on the type of element it represents.

When creating stress isometric drawings, my team typically exports a .dxf file of the AutoPIPE Model. We are only concerned with nodes that represent support locations, however, there is no option to export only support nodes. Having this option a...
Guest over 3 years ago in AutoPIPE Pipe Stress 1 Future consideration

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio over 1 year ago in Modelling 0 Future consideration

Ring Tool - Ability edit or modify the settings of an existing ring

Users cannot edit or modify existing rings. This is costing significant manhours to redo Ring Placement if the user forgets something during the initial ring placement.
Sujaan Ahamed Fareed 11 months ago in Modelling 0 Needs review

Import Caesar II model

I would like to import a Caesar II model. However, I was not able to. I asked for Bentley's tech support help, but I was directed to look at 'Import a Caesar II Neutral (CII) File' from AutoPIPE's help. It is just a general guide. There were a few...
Guest 4 months ago in Modelling 1 Needs review

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
Michael Wood over 1 year ago in AutoPIPE Pipe Stress 1 Future consideration

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest over 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest over 1 year ago in AutoPIPE Pipe Stress 3 Already exists

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 2 Future consideration

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Ahamed Fareed over 1 year ago in AutoPIPE Pipe Stress 0 Planned