Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 107 of 107

Specifying sub-report item under batch run by ntl files

I want to customize the output report items for an automation process. I'm building the system by ntl file. The dat file can customize them but the ntl file cannot.
Guest about 1 year ago in Reporting 1 Needs review

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
Guest about 1 year ago in Analysis / AutoPIPE Pipe Stress 0 Future consideration

Improve reference loads dialog

Add a toggle between X/Y/Z and axial/shear/bending/torsion for forces and moments in the reference loads dialog. Many allowables for connections are given in terms of total shear load or bending moment. It is not possible to use the current refere...
Michael Wood about 1 year ago in AutoPIPE Pipe Stress / UI 0 Future consideration

Second UI Window for docking dialogs, tools and grids

Autopipe has multiple windows, tools, floating windows, grids and other UI Elements. For users that use multiple monitors, The above UI Elements often move around, and re orient themselves. By providing the user with a second UI Application Window...
Sujaan Ahamed Fareed about 1 year ago in AutoPIPE Pipe Stress / UI 1 Future consideration

Evaluate ASME B16.5/47 flanges per ASME BPVC VIII-1 UG-44(b)

ASME B31.3-2022 F312 FLANGED JOINTS suggests using UG-44(b) "for qualifying piping external loadings on welding neck flanges". UG-44(b) is a modification of the very conservative equivalent pressure method.
Sean Pellerin about 1 year ago in AutoPIPE Pipe Stress 2 Future consideration

AccuDraw functionality to be able to select, place and move components

This will be a huge improvement with the ability to interact with Autopipe. Currently, users have to use a coordinate system, and map out changes to the Autopipe Mode. A feature similar to Accudraw in Microstation would significantly improve the a...
Sujaan Ahamed Fareed about 1 year ago in AutoPIPE Pipe Stress 1 Future consideration

On screen Code Stress Pass/Fail Indicator

During the development of pipe design, one may need to iteratively. make small changes, and check the impact on stress, Forces, Restraint forces, etc. It would save a lot of time if there was an indicator on the default main UI that states the hig...
Sujaan Ahamed Fareed about 1 year ago in AutoPIPE Pipe Stress 4 Future consideration

Fix AutoPIPE window position on multiple monitors

When using AutoPIPE with multiple monitors, there are several scenarios in which a window positions will get messed up. One example is the interactive results box will sometimes become very tall, with the results still shown at the top and then bl...
Michael Wood over 1 year ago in AutoPIPE Pipe Stress 1 Future consideration

One Button Z Up Conversion

When exporting a file to a DGN, one can easily click a button to transpose the model from Y up to Z up. It would be very handy if this could be done in the AutoPIPE model itself. Then one could simply click a button to change a file from Y up to Z...
Michael Cummings over 1 year ago in AutoPIPE Pipe Stress 5 Needs review

Increase maximum number of static earthquake load cases.

When using nonlinear analysis earthquake loads cannot be scaled. If additional analysis sets are required with different earthquake accelerations for design purposes, it is severely limiting to have only 30 E cases. There are 100 analysis sets, it...
Michael Wood over 1 year ago in AutoPIPE Pipe Stress 0 Future consideration