Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

FILTER BY CATEGORY

All ideas

Showing 83 of 83

Combination Reorganization

In the screenshot in the attached link, for example, i would like to move the highlighted combinations between LC130 and LC131. Does this make sense? As far as I know, the only way to do this is to duplicate LC131 to LC148 and then delete them. Li...
Guest over 2 years ago in AutoPIPE Pipe Stress 1 Future consideration

Wind load acc. to EN 1991-1-4 (Wind)

In the European Union we design wind loads acc. to EN 1991-1-4 (Wind), hence it would be nice if wind loads are implemented as in other pipe stress analysis programs.
Guest 4 months ago in AutoPIPE Pipe Stress 0 Needs review

Snow loading acc. to EN 1991-1-3 (Snow)

In the European Union we design acc. to EN 1991-1-3 (Snow), hence it would be nice if snow load are implemented as in other pipe stress analysis programs.
Guest 4 months ago in AutoPIPE Pipe Stress 2 Future consideration

Looking for DNV-ST-F101, 2021 edition in AutoPIPE

When we will expect new DNV version in AutoPIPE
Guest 6 months ago in Code 1 Future consideration

Increase allowable number of internal data points from 10,000 to 100,000 or more

AutoPIPE's analysis is blocked if total number of points (piping points+ soil points + frame nodes) is greater than 10,000. Suggest to increase the limit number of node points from 10,000 to 100,000 or more.
Mike Dattilio 6 months ago in Modelling 0 Future consideration

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest 9 months ago in AutoPIPE Pipe Stress 1 Already exists

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Fareed 9 months ago in AutoPIPE Pipe Stress 2 Future consideration

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Fareed 9 months ago in AutoPIPE Pipe Stress 0 Future consideration

Bolt Pre Tension

Possibility to declare bolt pre tension (eg, 40% or 50% of bolt SMYS) has to be provided in the Flange check.
Guest over 1 year ago in AutoPIPE Pipe Stress 0 Needs review

Group Segments

Add the ability to group a selection of segments to be easily selected
Guest over 1 year ago in AutoPIPE Pipe Stress 0 Future consideration