All ideas

Showing 109 of 109

Increase the number of SAM / Support Groups

AS of AutoPIPE 23.00.00.230, the maximum number of unique response spectrums that can be analyzed is 200 [(S1..S10)x 20 support groups per SAM case]. Suggest to Increase the number of SAM and/or Support Groups in order to allow 200+ unique respons...
Mike Dattilio 9 months ago in Analysis 0 Needs review

Add TOTAL RUN TIME FEATURE/LOG to AutoPIPE Analyses

For large AutoPIPE analyses especially, it would be VERY helpful to know how long an AutoPIPE analysis took to run! I think the a log file with the time stamp, what analyses were run, and the total run time would probably be the best option. A pop...
Guest almost 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Add EN13941 functionality

New Oil and Gas projects may dry up as more countries set their sights on net zero. Along with this there is currently a massive increase in the number of large scale district heating systems in both Europe and North America. Adding EN13941 functi...
Guest about 3 years ago in AutoPIPE Pipe Stress 0 Future consideration

Create and Save selection set of node points and beam points

As of July 2023, after making a selection set (highlighted red) it may become unselected when choosing the next command or another location that is not apart of the selection set. The user may need to perform another command / modification to a pr...
Mike Dattilio 9 months ago in Modelling 0 Needs review

Add trunnions and connected supports to Stress Isometric

Stress ISOmetric, I would like to see the trunnions shown along with their attached supports This will definitely save time having to annotate stress isos to show the missing pipe supports with the trunnions.
Mike Dattilio over 3 years ago in AutoPIPE Pipe Stress 2 Future consideration

Modeling soils in AutoPIPE should be simplified

In my opinion modeling of soils in AutoPIPE takes to much time and could/should be simplified. For selected part of the model, including simultanously vertical, horizontal or inclined segments, there are four geometrical methods to define a terrai...
Guest almost 2 years ago in AutoPIPE Pipe Stress 2 Future consideration

Support Results grids local direction should be user friendly and consistent

Open the results grids, select the support tab, and locate the columns for LocalDir1 - Gap3. Quick what does this refer to: pipe local axis, support local axis? Is this direction consistent across all of the support types (see attached image of Su...
Mike Dattilio 12 months ago in Reporting 0 Needs review

Unlock Springs for HydroTEST

Provide an option for unlocking Springs and Constants on the support definition dialog. Set default to Lock and allow Unlock during Hydrotest
Mike Dattilio over 3 years ago in AutoPIPE Pipe Stress 2 Future consideration

100-40-40 spatial combination option

In Response Spectra Analysis, the spatial combination is always SRSS. The NRG 1.92 rev. 2 accepts as an alternative the use of the 100-40-40 method, as proposed by Newmark, to spatially combine the components. An option to select between SRSS or 1...
Edgar Flores over 2 years ago in AutoPIPE Pipe Stress 0 Future consideration

Use AutoPIPE valve weights when importing PCF files

When importing files (such as PCF's) please provide the option to use AutoPIPE valve weights rather than using the weights from the original design tool that created the PCF file. Essentially having the option to automatically enable the "valve wr...
Guest over 2 years ago in AutoPIPE Pipe Stress 0 Future consideration