Add EN13941 functionality

New Oil and Gas projects may dry up as more countries set their sights on net zero. Along with this there is currently a massive increase in the number of large scale district heating systems in both Europe and North America. Adding EN13941 funct...
Guest 9 months ago in Code 0

Add option to enter Specific Gravity of contents referenced to Air instead of Water

The Specific Gravity based on water is not applicable to flow services that are 100% gas. Specific gravity for liquid is weight of liquid with respect to water and specific gravity of gas is weight of gas with respect to air. These 2 fluids are to...
Guest about 1 year ago in  2 Planned

100-40-40 spatial combination option

In Response Spectra Analysis, the spatial combination is always SRSS. The NRG 1.92 rev. 2 accepts as an alternative the use of the 100-40-40 method, as proposed by Newmark, to spatially combine the components. An option to select between SRSS or 1...
Edgar Flores 29 days ago in Analysis 0

Always enable "Use weight factor for bolt/nut weight" when importing a flange

When importing a PCF file please allow for the option to enabler "Use weight factor for bolt/nut weight" for flanges
Guest 4 months ago in Analysis 0

Use AutoPIPE valve weights when importing PCF files

When importing files (such as PCF's) please provide the option to use AutoPIPE valve weights rather than using the weights from the original design tool that created the PCF file. Essentially having the option to automatically enable the "valve wr...
Guest 4 months ago in Analysis 0

Allow manual entry of wind topographic factor Kzt

No description provided
Karim Rinawi 4 months ago in Modeling 0

Allow import of large coordinates from CAD systems

Currently AutoPIPE have an option to shift the coordinates when importing PCF files with large coordinates (more than 6 digits). Also if this option is not selected, the piping import will fail as the pipe lengths would be messed up.I understand t...
Karim Rinawi 4 months ago in Modeling 0

B31E code option

Add an option to use B31E (Standard for the Seismic Design) section 3.4 equation and the SSRS load combinations
Guest 8 months ago in Code 1 Planned

Add TOTAL RUN TIME FEATURE/LOG to AutoPIPE Analyses

For large AutoPIPE analyses especially, it would be VERY helpful to know how long an AutoPIPE analysis took to run! I think the a log file with the time stamp, what analyses were run, and the total run time would probably be the best option. A p...
Guest 9 months ago in  0 Planned

Unlock Springs for HydroTEST

Provide an option for unlocking Springs and Constants on the support definition dialog. Set default to Lock and allow Unlock during Hydrotest