Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

Reporting

Showing 20 of 148

Add design margins to piping loads being sent to structural

When it comes to exporting pipe support loads from AutoPIPE to STAAD, PipeLINK is an effective tool. While PipeLINK has most of the necessary functionality, there is a lack in the ability to add a Design Margin to the pipe support loads sent from ...
Guest 10 months ago in Reporting 4 Needs review

Support Report: Remove all global results from Local columns

For V-stops and Hanger support types, the Support report prints global values as local values. Example, see attached image. Notice the Global axis direction is different from the indicated pipe's local axis direction. Next notice the support's Loc...
Mike Dattilio 14 days ago in Reporting 0 Needs review

Support Results grids local direction should be user friendly and consistent

Open the results grids, select the support tab, and locate the columns for LocalDir1 - Gap3. Quick what does this refer to: pipe local axis, support local axis? Is this direction consistent across all of the support types (see attached image of Su...
Mike Dattilio almost 2 years ago in Reporting 1 Needs review

Specifying sub-report item under batch run by ntl files

I want to customize the output report items for an automation process. I'm building the system by ntl file. The dat file can customize them but the ntl file cannot.
Guest almost 2 years ago in Reporting 1 Needs review

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
Gianludovico Spizuoco 11 months ago in Reporting 1 Future consideration

Report Sign-Max for Support and Restraint in Results

It would be very handy for AutoPIPE to report the maximum loading for all load cases for reporting to the structural engineer or equipment manufacturers.
Sean Pellerin over 1 year ago in Reporting 3 Already exists

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest over 1 year ago in Reporting 1 Future consideration

Exporting .DGN of Code Stresses Color Graphics

Adding an option to export the Maximum Code Stresses Color Graphics in .DGN format. The user can utilize this feature to present the code stresses in a more visual way in Navisworks.
Fouad Tabbaq 7 days ago in Reporting 0 Needs review

Include option to extract displacement results (at node points) in local axes

Nodal displacement results in local axes would be immensely useful. I use AutoPIPE for onshore pipelines which are not straight & reviewing the displacement locally is often needed.
Guest 2 months ago in Reporting 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
Guest 5 months ago in Reporting 0 Needs review