ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 84

Add new support type for wall and roof penetrations

We typically model wall and roof penetrations as guides with clearance gaps of approximately 0.5 to 1.5 inches in all directions. These modeled clearances are then used to verify load transfer and confirm that the gaps are adequate at each penetra...
Karim Rinawi about 1 month ago in Modelling 0 Needs review

Separate the Support Forces Global Direction column by x, y, and z

About the support forces of the Excel Report of the report manager The Global_Direction outputs the same column, but users need to separate them by X, Y, Z. Please develop the AutoPIPE to separate the column by x, y, and z?
Yasushi Nagao about 1 month ago in Reporting 1 Needs review

Excel report manager: automatically skip missing section of selected saved report for current model

Problem: While using Excel report manager, selecting an existing save report to be applied to the current model displays the following message: "Report not compatible with the currently opened Database". This occurs because the original model use ...
Mike Dattilio about 1 month ago in Reporting 0 Needs review

Improve HIGH CONTRAST Colors

I have difficulty seeing text in AutoPIPE as it doesn't update along with high contrast in Windows.
Guest about 1 month ago in UI 0 Needs review

Add load factor to excel reports

When loads are sent to structural or equipment manufacturers, we often apply a factor of conservatism to cover small changes that might occur in the model. While exporting the results to an excel file is useful, the need to apply a load factor req...
Guest about 2 months ago in Reporting 1 Needs review

Include ASME B16.5 dimensions in EN1591 Flange Analysis

Currently, the EN1591 flange analysis only includes PN flange dimensions. Theoretically, you could manually input all the dimensions for an ASME flange but that would be extremely tedious to do every time. There is some ambiguity/"looseness" with ...
Sean Pellerin 3 months ago in Analysis 1 Needs review

Add filter features to Results Grids interface

Suggest, the following: List all filters in header section of the Results Grids (see attached screen shot). Retain filter settings to be reused when the Results Grids command is used again. Easy means of removing one or all current filter se...
Mike Dattilio 3 months ago in Reporting 0 Needs review

Add UK gas code IGE/TD/12

No description provided
Shrey Sharma 3 months ago in Code 0 Needs review

Add number of nodes per segment to "re-order segments" to sort by large segments

Only the first 26 segments A to Z can have 999 nodes, e.g. A00 to A999. Other segments can only have 99 node, e.g. AA00 to AA99. Sorting by the number of nodes in the segment can help order these segments so that segments A to Z have the larger nu...
Karim Rinawi 3 months ago in UI 0 Needs review

Export DGN, DB and others using DataAPI

This functionality would be very advantageous for post-processing results. I currently have scripts to convert dgn to dwg (and adjust according to my delivery standard) in addition to accessing the .db to generate an organized excel with the relev...