Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

FILTER BY CATEGORY

Modeling

Showing 7 of 33

Why there is no option what components to show after clicking the show component dialog box

Hello,When you work with a model that consiously you hide different kind of components in it, and then you want to show only one kind of hidden components for example the guide supports, it turns out that such a function does not exist in Autopipe...
Wojciech Augustyn 2 months ago in Modeling 0

Modeling soils in AutoPIPE should be simplified

In my opinion modeling of soils in AutoPIPE takes to much time and could/should be simplified. For selected part of the model, including simultanously vertical, horizontal or inclined segments, there are four geometrical methods to define a terrai...
Guest 3 months ago in Modeling 1

Allow manual entry of wind topographic factor Kzt

No description provided
Karim Rinawi about 1 year ago in Modeling 0

Allow import of large coordinates from CAD systems

Currently AutoPIPE have an option to shift the coordinates when importing PCF files with large coordinates (more than 6 digits). Also if this option is not selected, the piping import will fail as the pipe lengths would be messed up. I understand ...
Karim Rinawi about 1 year ago in Modeling 0

Release limitation of PIPE ID character length

Users of a company in Japan name PIPE ID under specific rule in P&ID and 3D-CAD while AutoPIPE has a limitation for PIPE ID's character length as 8 words. So they convert the PIPE ID for AutoPIPE limitation, but there is a possibility that it ...
Guest about 1 year ago in Modeling 0

Angle measurement

It is important to know not only the distance between the two points but also the angle of the pipe with respect to the coordinate axes during creating and modifying a model. I would like you to add another item to the Tools menu called Angle Meas...
Guest over 1 year ago in Modeling / UI 0 Planned

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest over 1 year ago in Modeling 0 Planned