ADD A NEW IDEA

Search results: Analysis

Showing 5 of 13

Add the capability to analyse multiple piping codes in a single model

Whilst using AutoPIPE Nuclear to assess pipework to ASME III, the models included different regions of pipework that were required to be assessed to ASME III Class 1 and Class 2 respectively. As it is not possible to assess to two different piping...
Guest 10 months ago in Analysis 4 Future consideration

Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains ...
Guest 10 months ago in Analysis 0 Needs review

Apply wind Shape factor to pipe properties instead of everything as it varies due to geometry in AS1170.2

You currently only have 1 place to input the Wind shape factor and this is applied to all pipes but the value is different for each diameter in Accordance with AS1170.2. This value could be input in the pipe properties for individual pipe sizes, t...
Paul Nielsen 6 months ago in Analysis 0 Needs review

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
Paul Nielsen about 1 year ago in Analysis 0 Future consideration

User to select spring from list of springs returned by Spring hanger analysis command

After running a hanger selection analysis with the currently defined hanger analysis parameters, 1 or more possible spring hangers that meet the criteria are reported, starting with the longest range and highest spring rate and finishing with the ...
Mike Dattilio about 2 years ago in Analysis 1 Needs review