Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

Search results: AutoPIPE Pipe Stress

Showing 5

Add the capability to analyse multiple piping codes in a single model

Whilst using AutoPIPE Nuclear to assess pipework to ASME III, the models included different regions of pipework that were required to be assessed to ASME III Class 1 and Class 2 respectively. As it is not possible to assess to two different piping...
Guest 10 months ago in Analysis 4 Future consideration

Flexible Joint Step Function Stiffness

Looking for an update to flex coupling input box to better model flexible coupling behavior. Flexible joint additional inputs (see attached) 1) Max angle of deflection for flex joint 2) Two stiffness inputs for bending stiffness. Stiffness changes...
Guest about 2 years ago in Modelling 0 Future consideration

Increase tag length or remove the restriction altogether (like Caesar II)

The current max length of tags is 36 characters. Tag is meanwhile just about the only play where we can save some element-specific information. For example in the case of a Support I would like to save AT LEAST the following:1) The designation of ...
Guest about 4 years ago in AutoPIPE Pipe Stress 0 Future consideration

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
Paul Nielsen about 1 year ago in Analysis 0 Future consideration

ASME Flange Summary to show both Operating and Seating in separate columns

Currently the results summary will show the worst case for the flange. ASME B16.5 flanges combined with spiral wound gaskets will commonly fail the seating condition check with the ASME division 1 checks. This can be ignored provided the operating...
Paul Nielsen about 1 year ago in Reporting 0 Future consideration