Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.
You have 3 options for providing feedback:
VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.
COMMENT on an existing idea. We want to hear your unique point of view.
ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.
When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.
hi. It is important to be able to correctly model EnTyoe A and B fittings. Right now I have a spreadsheet where I multiply the calculated code stress with the allowed type A fitting utilization ratio. Especially the tees at weak wit approx 25% allowed utilisation. Even when doing this there is an error in the sif factors of the fittings used because they consider type B reinforced fittings like in ASME. Programs like ROHR2 correctly calculates this. Br Erik.