Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 109 of 109

Unlock Springs for HydroTEST

Provide an option for unlocking Springs and Constants on the support definition dialog. Set default to Lock and allow Unlock during Hydrotest
Mike Dattilio over 3 years ago in AutoPIPE Pipe Stress 2 Future consideration

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
Guest about 1 month ago in Analysis 0 Future consideration

Bring back the Bentley AutoPIPE User Accreditation Program

As per the note in read on the top of this page, please bring back the user accreditation program
Hubert Velten about 2 months ago in AutoPIPE Pipe Stress 1 Needs review

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
Gianludovico Spizuoco about 2 months ago in Reporting 1 Future consideration

Allow load combination re-sorting or insert

In the load combination options, users can custom define loads. The combination ordering is specific to the entries - the rows at the bottom can use previous combinations above, but not v/v. AutoPIPE generates an error if a load case tries to refe...
Guest 2 months ago in UI 0 Planned

User .DFL file as seed file for project specification

AutoPIPE currently provides a default setting file that can be used to control how a new model is created. We want to expand this to include most options, settings and material information, make it shareable and use it as a seed file. Would this b...
Phil Senior 6 months ago in Modelling 0 Planned

Add Cut-shorts to View Settings/Scale Factors

Users cannot change the size of cut-short symbol. The cut-short symbol is drawn proportional to the pipe OD while in single line mode. It sometimes looks too big or too small.
Guest 6 months ago in UI 0 Needs review

Report Sign-Max for Support and Restraint in Results

It would be very handy for AutoPIPE to report the maximum loading for all load cases for reporting to the structural engineer or equipment manufacturers.
Sean Pellerin 7 months ago in Reporting 3 Already exists

Fix the Load Sequencing for Snow Load

The help file states the following for snow load analysis: Limitation Currently, AutoPIPE only considers snow loading as linear analysis. Load sequencing does not apply to snow loads and such results should not be considered. For analysis sets tha...
Sean Pellerin 8 months ago in Analysis 0 Needs review

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest 8 months ago in Reporting 1 Future consideration