PCF import: add feature to map component attributes to over-ride default mappings

I think there should be a feature for component attributes mapping on a GUI (dialog) so users can over-ride the default mappings. I am thinking of following grid like GUI. Also suggest to have a button in order to restore defaults so if anyone wis...
Mike Dattilio about 5 years ago in AutoPIPE Pipe Stress 2 Future consideration

add user define on spring "hot load input" and let the program design spring rate, Cold load and variation checking

No description provided
Guest almost 2 years ago in Analysis 0 Future consideration

Output Modal Solution/mass participation

AutoPIPE error 1304731 indicates that there are improper combinations of the modal solutions for seismic anchor motions and seismic response spectra. The "fix" to the error report is a warning to the end-user; however, there is no work around. Oth...
Guest almost 2 years ago in Reporting 3 Already exists

Hydrotest Pressure Extension

Users can decide whether pressure extension should be considered in static analysis sets, but this is not an option for hydrotest cases. The user is required to consider it with no option to unselect "Pressure Extension" in the "Analysis Sets" int...
Guest almost 2 years ago in Analysis 2 Future consideration

Include UID number in "Result" mdb output.

In our work process we create PCF file using S3D. After analyzing data inside Autopipe we would like to export some of the analyzed data from Autopipe and import back to S3D. Easiest way to achieve that would be by using UID number of the analyzed...
Guest almost 2 years ago in Reporting 0 Needs review

100-40-40 spatial combination option

In Response Spectra Analysis, the spatial combination is always SRSS. The NRG 1.92 rev. 2 accepts as an alternative the use of the 100-40-40 method, as proposed by Newmark, to spatially combine the components. An option to select between SRSS or 1...
Edgar Flores almost 4 years ago in AutoPIPE Pipe Stress 0 Future consideration

Flexible elements displacement results in element local axes

having flexible elements displacements results reported in local element axes, provides a better way to quantify relative end displacements and avoids doing global to local axes transformation out of the software. Amount of end and intermediate di...
Guest about 2 years ago in AutoPIPE Pipe Stress 1 Already exists

Use AutoPIPE valve weights when importing PCF files

When importing files (such as PCF's) please provide the option to use AutoPIPE valve weights rather than using the weights from the original design tool that created the PCF file. Essentially having the option to automatically enable the "valve wr...
Guest about 4 years ago in AutoPIPE Pipe Stress 0 Future consideration

Output file should describe number of Warning/Error conditions encountered

Analysis quality will improve if AutoPIPE Output Report (SQO) describes the number of Warning/Error conditions encountered together with a recommendation to view .CHK, .DCHK, .ANL and any other Warning/Error files present. The lack of a recommenda...
Guest about 2 years ago in Analysis 0 Needs review

CMB Files keep dropping off after importing

The load combinations keep having to be updated by re-importing the CMB file constantly when doing the analysis. Making the imported CMB files more stable to where the user do not have to keep re-importing them so often would be a good idea to imp...
Fouad Tabbaq over 4 years ago in AutoPIPE Pipe Stress 1 Future consideration