ADD A NEW IDEA

Analysis

Showing 25

add user define on spring "hot load input" and let the program design spring rate, Cold load and variation checking

No description provided
Guest 10 months ago in Analysis 0 Future consideration

Hydrotest Pressure Extension

Users can decide whether pressure extension should be considered in static analysis sets, but this is not an option for hydrotest cases. The user is required to consider it with no option to unselect "Pressure Extension" in the "Analysis Sets" int...
Guest 10 months ago in Analysis 2 Future consideration

Defining Concentrated force to the local axis of element

The inability to specify the concentrated force for the local element in Autopipe leads to numerous challenges when defining the slug force on a pipeline that is misaligned with the axis. In contrast to CAESAR, Autopipe lacks the capability to rot...
Guest 11 months ago in Analysis 0 Planned

Output file should describe number of Warning/Error conditions encountered

Analysis quality will improve if AutoPIPE Output Report (SQO) describes the number of Warning/Error conditions encountered together with a recommendation to view .CHK, .DCHK, .ANL and any other Warning/Error files present. The lack of a recommenda...
Guest over 1 year ago in Analysis 0 Needs review

Increase the number of SAM / Support Groups

AS of AutoPIPE 23.00.00.230, the maximum number of unique response spectrums that can be analyzed is 200 [(S1..S10)x 20 support groups per SAM case]. Suggest to Increase the number of SAM and/or Support Groups in order to allow 200+ unique respons...
Mike Dattilio over 1 year ago in Analysis 0 Needs review