Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

All ideas

Showing 108 of 108

Add Node Annotations to stress isometric

AutoPIPE's Node Annotations (Insert > Node Annotations) are not able to be printed on a Stress Isometric. Using the "save isometric drawning" prompt, we have the option to isert annotations (but it's not a good way to do it), and it's not relat...
Guest 8 months ago in Modelling 0 Needs review

Non-nuclear Fatigue Analysis

I am planning to include non-nuclear fatigue in a future release. We already support ASME III NB method for nuclear and want to provide a general approach to be used with other design codes. I am looking for interest in the idea and any suggestion...
Phil Senior 8 months ago in Analysis 2 Future consideration

Total Length of Pipe

Once pipe properties are assigned to a run, the total length of the run with that property is calculated. For example I have 3 runs, a 2ft run, 4 ft run and 2 ft run. I assigned the property of A335P11 to the 2ft runs and SS36 to the 4ft run. Auto...
Guest 8 months ago in Reporting 1 Future consideration

Increase the number of SAM / Support Groups

AS of AutoPIPE 23.00.00.230, the maximum number of unique response spectrums that can be analyzed is 200 [(S1..S10)x 20 support groups per SAM case]. Suggest to Increase the number of SAM and/or Support Groups in order to allow 200+ unique respons...
Mike Dattilio 8 months ago in Analysis 0 Needs review

Add capability to model 2 springs in series

Spring hanger arrangement, see attachment.
Mike Dattilio 8 months ago in Modelling 0 Needs review

Model new piping geometry based on newly established local coordinate system instead of Global coordinate system

Use Case: If The entire model is using plant coordinates thus causing the entire system to be off AutoPIPE's global axis. Then, if the user needs to add new piping geometry it is very difficult to model in AutoPIPE using global coordinates. Users ...
Mike Dattilio 8 months ago in Modelling 0 Needs review

Create and Save selection set of node points and beam points

As of July 2023, after making a selection set (highlighted red) it may become unselected when choosing the next command or another location that is not apart of the selection set. The user may need to perform another command / modification to a pr...
Mike Dattilio 9 months ago in Modelling 0 Needs review

Color plot: Connected Segments

Provide a color map based on the Connected Segments (Select > Segments > Connected Segments). For each disconnected group have a unique color assigned.
Mike Dattilio 9 months ago in Modelling 0 Needs review

Upgrade Steam relief to include other gas & liquid relief thrust analysis

Currently The Loads > Steam Relief > Steam Relief command enables the user to define the thrust loads at steam exit points due to a discharge through a safety relief valve. Add ability for program to analyze other gas & liquid relief val...
Mike Dattilio 9 months ago in Analysis 0 Needs review

Add China Electric Power industry standard DL/T 5366

At present, the pipeline stress calculation specification is selected as the American standard, whether it is considered to refer to the Chinese standard DL/T 5366-2014. If there is no reference to this standard, then please ask whether this stand...
Mike Dattilio 9 months ago in Code 0 Needs review