Hide feature for concentrated forces

I use Auto pipe to run stress analysis, and I always write a report summarizing the results. I always include screenshots of the restraint and supports reactions. The concentrated forces are necessary to include in the calculations, but for the sc...
Guest 7 months ago in AutoPIPE Pipe Stress 0 Needs review

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
Guest 8 months ago in Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
Guest 8 months ago in Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
Sean Pellerin 8 months ago in Reporting 2 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
Mike Dattilio 8 months ago in Reporting 0 Needs review

Import multiple load cases from pcf files

We are trying to reduce the steps required to edit piping in initial design. We have multiple transients that all have to be accounted for. In order to hold a consistent model, we are trying to make any and all changes in SolidWorks and import int...
Guest 8 months ago in UI 6 Planned

Add label box for flexible joints

It would be helpful if flexible joints could have a label or tag added. This would be similar to how many components in AutoPIPE have the ability to label components, such as supports and anchors.
Michael Cummings about 2 years ago in UI 1 Future consideration

Allow user to set the 6 color stress plot ranges as needed

While looking at the Color Stress plot there is a Key in the top left corner with 6 colors and corresponding ranges. These ranges are hard coded into the program. Give the user the options to set these 6 ranges as needed.
Mike Dattilio about 2 years ago in UI 3 Future consideration

Apply joint efficiency factor to ASME B31.1 Expansion allowable

As an example, ASME B31.1 (2020) - section "102.3.2 Limits for Sustained Stresses and Displacement Stress Ranges" - para (b) Displacement Stresses provides the equation 1A for calculation of allowable stress range. Review the definition of Sc and ...
Mike Dattilio about 2 years ago in Analysis 2 Future consideration

Specifying sub-report item under batch run by ntl files

I want to customize the output report items for an automation process. I'm building the system by ntl file. The dat file can customize them but the ntl file cannot.
Guest about 2 years ago in Reporting 1 Needs review