ADD A NEW IDEA

AutoPIPE Pipe Stress

Showing 82

Export the Component_GUIDs fields

Support the Component_GUIDs fields to be export, so that we can compare the entity with origin entity from other software.
Guest about 1 year ago in Reporting 0 Needs review

Add redundant anchor for thermal load only

As AutoPipe limited node to 10000 only, for bigger model we model part of the system and we need to apply boundary conditions at the discontinuous node, if it is defined as anchor and apply node displacement (for thermal growth) this fictitious an...
Guest about 1 year ago in Analysis 0 Needs review

Easily uncheck print combinations that are inconsistent with the default load sequence.

Create button to uncheck print for load combinations that are inconsistent with the default load sequence.
Sean Pellerin about 1 year ago in Reporting 2 Needs review

Add a method to acknowledge Warning message as to not constantly appear.

When reviewing Model Consistency Check report, some warning messages will constantly appear regardless of addressing the warning. Example W726-10:  User SIF required at junction  at following point(s) Require a feature be added where reo...
Mike Dattilio about 1 year ago in Reporting 0 Needs review

Add China Electric Power industry standard DL/T 5366

At present, the pipeline stress calculation specification is selected as the American standard, whether it is considered to refer to the Chinese standard DL/T 5366-2014. If there is no reference to this standard, then please ask whether this stand...
Mike Dattilio over 2 years ago in Code 0 Needs review

Copy & pasting pipe components with existing soil Id's are not updated with new Soil Id names

Open PipeSoil.apc Notice the Soil id currently in the model. Select all of the model. Paste to any location after pasting, notice the number of Soil Id's has doubled. Recommend when coping / pasting pipe node points with existing Soil Id's that th...
Mike Dattilio over 2 years ago in Modelling 0 Needs review

Display response spectrum acceleration results using the 'interactive' results viewer (showing deformed model and acceleration values)

The AutoPIPE 'interactive" menu has a way to display displacement results and filter results. Presently, the acceleration results in a response spectrum analysis are only viewable from the text result files or excel reports. Having a GUI accelera...
Guest over 2 years ago in UI 0 Needs review

Carbon Steel Flange Material

It would be extremely useful to add additional carbon steel flange material to the database drop down list. In my experience, the majority of the pipelines are comprised of the materials shown below and their flanged equivalent. Please add the fol...
Guest over 1 year ago in Analysis 0 Needs review

User to select spring from list of springs returned by Spring hanger analysis command

After running a hanger selection analysis with the currently defined hanger analysis parameters, 1 or more possible spring hangers that meet the criteria are reported, starting with the longest range and highest spring rate and finishing with the ...
Mike Dattilio over 2 years ago in Analysis 1 Needs review

Total Computing Power

I noticed that Autopipe uses a limited amount of computer power. In a time-history analysis with a modal frequency of 400hz on a relatively small model it took about 30min using only 6 to 9% of the computer's processing power. An improvement in pr...
Guest over 1 year ago in Analysis 3 Needs review