AutoPIPE Pipe Stress

Showing 136 of 138

Update Coincident Node Check report to include Beam points

Currently, coincident node check report only returns results for pipes nodes that are within the specified tolerance distance to another pipe node point. Suggest report also include Beam points with specified tolerance distance of other Beam point...
Mike Dattilio 6 months ago in Modelling 0 Needs review

Model Explorer: add the following features (ex. Tee type, Wave Type, etc..)

Please add the following features to AutoPIPE's Model Explorer: 1st approver 2nd approver Seismic code - indicate all in model to be selected Wind type - indicate all in model to be selected wave type - indicate all in model to be selected Materia...
Mike Dattilio 6 months ago in Reporting 0 Needs review

Import Caesar II model

I would like to import a Caesar II model. However, I was not able to. I asked for Bentley's tech support help, but I was directed to look at 'Import a Caesar II Neutral (CII) File' from AutoPIPE's help. It is just a general guide. There were a few...
Guest 7 months ago in Modelling 1 Needs review

Add design margins to piping loads being sent to structural

When it comes to exporting pipe support loads from AutoPIPE to STAAD, PipeLINK is an effective tool. While PipeLINK has most of the necessary functionality, there is a lack in the ability to add a Design Margin to the pipe support loads sent from ...
Guest 8 months ago in Reporting 4 Needs review

A need to track displacements of reference points?

how to track displacements of reference points? I understand that reference points are only used to track forces and moments but i want to see separately the displacement results of these reference points instead of manually searching node by node...
Guest 8 months ago in Analysis 1 Needs review

Extract system Response Spectra at decoupled connection points

The capability of producing FRS at some points is sometimes needed to analyze small bore branches. Generally, the small bore branches could be decoupled from the headers for seismic analysis, but these lines shall be evaluated separately using the...
Guest 9 months ago in AutoPIPE Pipe Stress 3 Future consideration

ASME Flange Summary to show both Operating and Seating in separate columns

Currently the results summary will show the worst case for the flange. ASME B16.5 flanges combined with spiral wound gaskets will commonly fail the seating condition check with the ASME division 1 checks. This can be ignored provided the operating...
Paul Nielsen 9 months ago in Reporting 0 Future consideration

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
Paul Nielsen 9 months ago in Analysis 0 Future consideration

Bring back the Bentley AutoPIPE User Accreditation Program

As per the note in read on the top of this page, please bring back the user accreditation program
Hubert Velten 9 months ago in AutoPIPE Pipe Stress 1 Needs review

Flange Ansi check as per UG-44: setting a user ratio for each rating

Ansi/kellogs method is a widely used way to check flange joint, but different standard, or client specification could use different allowable. Now the ASME BPVC VII UG-44 suggest 2.2 for B16.5 #150 and 1.5 for most of the others; DNV suggested 1.5...
Gianludovico Spizuoco 9 months ago in Reporting 1 Future consideration