ADD A NEW IDEA

All ideas

Showing 161 of 161

Wind load acc. to EN 1991-1-4 (Wind)

In the European Union we design wind loads acc. to EN 1991-1-4 (Wind), hence it would be nice if wind loads are implemented as in other pipe stress analysis programs.
Guest about 2 years ago in AutoPIPE Pipe Stress 0 Needs review

Enable different ambient temperatures for each thermal case

There is often need to calculate two conservative thermal combinations (lowest possible assembly temperature with highest working temperature and highest assembly temperature with lowest working temperature). Now it is needed to prepare two models...
Guest over 2 years ago in AutoPIPE Pipe Stress 3 Already exists

Dynamic interface between Autopipe and Openplant

Currently, the interface between Autopipe and Openplant is disconnected. Users have to manually export piping models to Autopipe, and perform analysis. If changes need to happen in one model, the other model isnt't updated dynamically. Further, th...
Sujaan Ahamed Fareed over 2 years ago in AutoPIPE Pipe Stress 2 Future consideration

Insert 2 node points when a flange is inserted, to allow the user to set the BW SIF

By default, when you insert a WN or Lap Joint flange in Autopipe, it does not account for SIF at the BW joint. User has to enter an additional node point at a flange length and define a Joint Type with a defined offset. This could be automated.
Sujaan Ahamed Fareed over 2 years ago in AutoPIPE Pipe Stress 0 Planned

Bolt Pre Tension

Possibility to declare bolt pre tension (eg, 40% or 50% of bolt SMYS) has to be provided in the Flange check.
Guest about 3 years ago in AutoPIPE Pipe Stress 0 Needs review

Add EN13941 functionality

New Oil and Gas projects may dry up as more countries set their sights on net zero. Along with this there is currently a massive increase in the number of large scale district heating systems in both Europe and North America. Adding EN13941 functi...
Guest about 4 years ago in AutoPIPE Pipe Stress 0 Future consideration

Add Feature to Allow Specific Gravity to be Changed for Different P/T Cases

At the moment, specific gravity is entered under Pipe Properties and cannot be changed for different pressure/temperature load cases. If there are different load cases, where a section of the model may be filled with water in Case 1 but filled wit...
Guest about 2 months ago in Modelling 0 Needs review

Bring back Access database export

Removing the Access database export has killed our work flow and we can not find a work around using SQLite.
Kevin Koorey 4 months ago in Reporting 1 Will not implement

Add ability to analyze multiple Analysis set at the same time

Currently AutoPIPE analyzes analysis sets one at a time. Between each analysis set the application writes the results of the analysis from the cache temp folder to the model folder. Models containing multiple analysis can take an extended period o...
Mike Dattilio 6 months ago in Analysis 0 Future consideration

Multiple Ambient Temps for Hot Tie-in Case

Does any means exist to enter multiple ambient temperatures for piping? For example: Case 1: Header with tie-in valve operating at 375F. Will fit up proposed piping at 70F to tie-in valve in hot position. After tie-in valve is open header remains ...