Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

Search results: Analysis

Consider Valve Surface Area Factor for Wind loading

Valve's surface area factor should be used while applying wind loading.
Mike Dattilio 25 days ago in Analysis Needs review

Correction of Gasket Seating Width Calculation in Flange Check (ASME VIII)

Currently, AutoPIPE calculates the gasket seating width (N) using the gasket outside diameter (OD) and inside diameter (ID), N=(Gasket OD-Gasket ID)/2. As per ASME Section VIII (Sketch 1a), the gasket seating width should be calculated based on th...
Tanaji Gaikwad 4 months ago in Analysis Needs review

Add Snow and Ice load to structural and pipe members

Snow loads should be considered in the GR load case during analysis and design for static seismic loads, to account for the contribution of snow mass to horizontal seismic inertia forces.
Shrey Sharma about 1 year ago in Analysis Needs review

Add ASCE-7-22

For wind loading ASCE-7-22 needs to be added in selection list. This is the latest standard and client design basis is demanding to use latest standard.
Guest 7 months ago in Analysis Planned

Component Level FRS

Similar to the attached PIPESTRESS Amplified Spectrum Generator, add a post-processing tool to AutoPIPE that can generate FRS at any node in the model (i.e., component-level FRS). This is useful when a small branch is decoupled from a large model ...
Guest 2 months ago in Analysis Needs review

Add manufacturer library for SIF's to populate to meet B31.J as per B31.3 2020

Add manufacturer library to select for SIF's to populate to meet B31.J as per B31.3 2020
Guest almost 3 years ago in Analysis Needs review

Add the capability to analyse multiple piping codes in a single model (Mixed Class)

Whilst using AutoPIPE Nuclear to assess pipework to ASME III, the models included different regions of pipework that were required to be assessed to ASME III Class 1 and Class 2 respectively. As it is not possible to assess to two different piping...
Guest about 2 years ago in Analysis Future consideration

Include ASME B16.5 dimensions in EN1591 Flange Analysis

Currently, the EN1591 flange analysis only includes PN flange dimensions. Theoretically, you could manually input all the dimensions for an ASME flange but that would be extremely tedious to do every time. There is some ambiguity/"looseness" with ...
Sean Pellerin 11 months ago in Analysis Reviewed

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
Guest over 3 years ago in Analysis / AutoPIPE Pipe Stress Future consideration

Add features to include Type A/B fitting pressure factor for En13480 piping code

Add options into application that accommodates En13480 table A.2 specification for all fittings per En10253 requirements to define pressure factors to be applied to fittings of Type A and wall thickness requirements of fittings of Type B. Add opti...
Shrey Sharma over 1 year ago in Analysis Needs review