Skip to Main Content
AutoPIPE Ideas Portal

Welcome to the AutoPIPE Ideas Portal. We value your feedback, and our team regularly reviews your ideas and considers them for future improvements to our products and services.

You have 3 options for providing feedback:

  1. VOTE for an existing idea. The popularity of an idea helps us understand its importance to the community.

  2. COMMENT on an existing idea. We want to hear your unique point of view.

  3. ADD a new idea. You can always submit a new idea if no existing one describes your suggestion.

When you add, vote or comment on an idea you will also be subscribed to that idea and receive status updates. Please note we may merge or rename ideas for better clarity for the community. Thank you for your support and feedback.

ADD A NEW IDEA

Analysis

Showing 7

Add the capability to analyse multiple piping codes in a single model

Whilst using AutoPIPE Nuclear to assess pipework to ASME III, the models included different regions of pipework that were required to be assessed to ASME III Class 1 and Class 2 respectively. As it is not possible to assess to two different piping...
Guest 3 months ago in Analysis 4 Future consideration

Reference point - nonsymmetric allowable

Reference point is great tool to verify connector capacity. Currently only symmetric allowable values could be used. Many times connectors allowable loads are nonsymmetric ex. range of values -80 to 0kN or -150 to 350kNm. See attached image. It wo...
Guest over 1 year ago in Analysis / AutoPIPE Pipe Stress 0 Future consideration

Add API 661 allowables to rotating equipment

Provide user ability to insert cooler nozzle allowables per API 661. This would help with cooler orientation and no longer require user to look up allowable values each time. Provide a multiplier allowable (i.e. 2x 3x API limits)
Guest about 1 year ago in Analysis 0 Future consideration

Turn off wind in 1 or more directions for segement

In some cases pipes are shielded from wind from walls etc, it would be helpful to be able to turn the wind off in that direction, on that segment, Currently you can only turn off all of the wind loads on a segment
Guest 8 months ago in Analysis 0 Future consideration

Apply joint efficiency factor to ASME B31.1 Expansion allowable

As an example, ASME B31.1 (2020) - section "102.3.2 Limits for Sustained Stresses and Displacement Stress Ranges" - para (b) Displacement Stresses provides the equation 1A for calculation of allowable stress range. Review the definition of Sc and ...
Mike Dattilio over 1 year ago in Analysis 2 Future consideration

add user define on spring "hot load input" and let the program design spring rate, Cold load and variation checking

No description provided
Guest 9 months ago in Analysis 0 Future consideration

Hydrotest Pressure Extension

Users can decide whether pressure extension should be considered in static analysis sets, but this is not an option for hydrotest cases. The user is required to consider it with no option to unselect "Pressure Extension" in the "Analysis Sets" int...
Guest 9 months ago in Analysis 2 Future consideration