Analysis

Showing 34

Allow small letters in point names to increase node limit to 40000

If increasing the length of point names to 5 or six letters is too hard, I suggest allowing the use of small letters aa to zz. This will increase the number of segments and number of nodes by 4 times to about 2800 segments and 40,000 nodes.
Karim Rinawi 27 days ago in Analysis 0 Future consideration

Add ASCE-7-22

For wind loading ASCE-7-22 needs to be added in selection list. This is the latest standard and client design basis is demanding to use latest standard.
Guest 30 days ago in Analysis 0 Planned

Add Cold Load Design global option to Hanger dialog

The Support dialog window and the Input Grid Support tab currently have the option to turn on/off Cold Load Design. The request is to supplement these two with a global override, by adding a Cold Load Design global option to the Hanger dialog wind...
Guest 2 months ago in Analysis 0 Planned

Expansion effects on structural members

Currently, when structural members/beams are connected to high temp piping, AutoPIPE does not consider the axial expansion effect of the structural members in its analysis. Since AutoPIPE, is capable of evaluating temperature effect of piping, it ...
Sujaan Ahamed Fareed 5 months ago in Analysis 0 Future consideration

Include ASME B16.5 dimensions in EN1591 Flange Analysis

Currently, the EN1591 flange analysis only includes PN flange dimensions. Theoretically, you could manually input all the dimensions for an ASME flange but that would be extremely tedious to do every time. There is some ambiguity/"looseness" with ...
Sean Pellerin 5 months ago in Analysis 1 Reviewed

Add Snow and Ice load to structural and pipe members

Snow loads should be considered in the GR load case during analysis and design for static seismic loads, to account for the contribution of snow mass to horizontal seismic inertia forces.
Shrey Sharma 6 months ago in Analysis 2 Needs review

Update Joint Type SIF Sus Tors Index to read "Auto" instead of "1.00"

When a Joint type and user SIF are inserted, the Sus Tors. Index value will actually be computed in the post processor. In the meantime, AutoPIPE displays a value of "1.00" in the dialog, which can be misleading for the user. It is recommended to ...
Mike Dattilio 7 months ago in Analysis 0 Needs review

Add features to include Type A/B fitting pressure factor for En13480 piping code

Add options into application that accommodates En13480 table A.2 specification for all fittings per En10253 requirements to define pressure factors to be applied to fittings of Type A and wall thickness requirements of fittings of Type B. Add opti...
Shrey Sharma about 1 year ago in Analysis 0 Needs review

Add ability to group analysis sets which represent different analysis cases

Piping Stress, Pipe Support, and Foundation load generation require different analysis conditions using different seismic loads to meet differing code requirements. Currently, this is difficult to manage in the same autopipe file as users may have...
Sujaan Ahamed Fareed about 1 year ago in Analysis 0 Needs review

Add ability to analyze multiple Analysis set at the same time

Currently AutoPIPE analyzes analysis sets one at a time. Between each analysis set the application writes the results of the analysis from the cache temp folder to the model folder. Models containing multiple analysis can take an extended period o...
Mike Dattilio about 1 year ago in Analysis 0 Future consideration